Skip to content

Water Quality Technical Report — LITCHFIELD, IL

PWSID
IL1350400
Population
6,648
Source
Surface Water
Data Period
—
Last Updated

A note from the author — I'm Jacob Thorwolf. WaterAdvantage.org is a personal project of mine, separate from my day job as an Account Executive at Bottleless Nation, a commercial water filtration company. If you request a consultation through any form on this site, it comes to me or a colleague at BN. More about this project →

Summary

LITCHFIELD serves approximately 6,648 people in LITCHFIELD, Illinois. Based on contaminant analyses from DNR, WQP, EPA ECHO, EPA UCMR5, 1 contaminant has been measured above federal EPA standards (MCL) and 2 exceed health-based guidelines. The most significant finding is Haloacetic Acids (HAA5) at 60.92 ug/L, which is 1x the EPA legal limit. Data is drawn from source-level compliance monitoring and covers 2000 through 2026. Results reflect conditions at the point of collection (wells, treatment plants), not necessarily at the tap.

Key Findings

Understanding the two thresholds

EPA Legal Limit (MCL)

The highest level of a contaminant allowed by federal law. Utilities that exceed this threshold face enforcement action. Limits balance health risk against the cost of treatment, so they are not always set at levels considered safe by independent researchers.

Health Guideline

The level below which independent researchers (CalEPA, WHO, EWG) believe there is no known health risk. Guidelines are not legally enforceable but are typically stricter than legal limits — often by 10x or more for contaminants like arsenic and lead.

A reading can be below the EPA limit (legally compliant) while still exceeding health guidelines (above levels considered safe by independent researchers).

Exceeds Health Guidelines

These contaminants were detected below the EPA legal limit but above a health-based guideline from a public health agency (CalEPA OEHHA, WHO, or similar). Health guidelines are non-enforceable research-backed targets that are often stricter than the legal limit.

Detected contaminants
ContaminantResultUnitHealth GuidelineEPA Legal LimitSourceSample Date
Lead (90th Percentile)
Developmental delays in children, kidney damage, high blood pressure. There is no safe level of lead exposure.
9.1ug/L0.215
Pending rule: LCRI 2024 — Action level drops from 15 → 10 µg/L effective 2027; full lead service line replacement within 10 years (EPA Lead & Copper Rule Improvements, October 2024)
EPA ECHO

Microplastics

Microplastics have been documented in raw and treated drinking water worldwide, but federal regulations do not currently require testing — so there is no data specific to this system. Standardized methods and rules are in progress.

Other Regulated Contaminants

These contaminants were detected within federal standards (EPA Maximum Contaminant Levels). They are presented for transparency.

Total Trihalomethanes (TTHMs) (LRAA): 52.40 ug/L — within limit of 80 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2HT2, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Total Trihalomethanes (TTHMs) (LRAA): 61.24 ug/L — within limit of 80 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2HH2, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Detected contaminants
ContaminantResultUnitHealth GuidelineEPA Legal LimitSourceSample Date
Nitrate (as N)
Blue baby syndrome in infants
3.3mg/L1010(as N)DNR
Atrazine
Cardiovascular system or reproductive problems
110ng/L1503000DNR
Barium
Increase in blood pressure
42ug/L10002000DNR
Fluoride (natural)
Bone disease, mottled teeth in children
847ug/L40004000DNR
Arsenic
Skin damage, circulatory problems, increased risk of cancer
200ng/L410000WQP(15+ years ago)
Chromium (total)
Note: total chromium includes the harmless trivalent form (Cr-III). The toxic hexavalent form (Cr-VI) has no federal MCL; California set a 10 µg/L Cr-VI MCL in 2014.
Allergic dermatitis
600ng/L100000100000WQP(15+ years ago)

Unregulated Detected Contaminants

These contaminants were detected but do not have a federal Maximum Contaminant Level. They are monitored for awareness, not compliance.

Other Substances

Detected contaminants
ContaminantResultUnitHealth GuidelineEPA Legal LimitSourceSample Date
Copper (90th Percentile)
Gastrointestinal distress at high levels. Long-term exposure can cause liver or kidney damage.
Per-source breakdown (57 sampling locations)
  • Sampling locationMost recent valueSample date
  • Well SCH002B546 ug/L9/22/26
  • Well SCH002A510 ug/L9/22/26
  • Well DAYCARE004B409 ug/L9/15/26
  • Well SCH002D333 ug/L9/22/26
  • Well SCH001A242 ug/L12/11/25
  • Well LC1T017163 ug/L9/20/26
  • Well SCH002E153 ug/L9/22/26
  • Well SCH001B112 ug/L12/11/25
  • Well DAYCARE001B109 ug/L12/5/25
  • Well DAYCARE008B95.9 ug/L12/10/25
  • Well SCH001D92.6 ug/L12/11/25
  • Well DAYCARE008A92.6 ug/L12/10/25
  • Well LC1T02190.8 ug/L9/25/26
  • Well SCH002C87.8 ug/L9/22/26
  • Well LC1T01480.3 ug/L9/19/26
  • Well DAYCARE004A58.5 ug/L9/15/26
  • Well SCH001C55 ug/L12/11/25
  • Well DAYCARE003B45.4 ug/L9/22/26
  • Well LC1T01844 ug/L9/16/26
  • Well LC1T01938.9 ug/L9/16/26
  • Well LC1T01534.7 ug/L12/8/25
  • Well SCH001E32.6 ug/L12/11/25
  • Well DAYCARE001A32.2 ug/L12/5/25
  • Well LC1T02431.8 ug/L9/28/26
  • Well LC1T03326.3 ug/L9/25/26
  • Well LC1T00225.5 ug/L9/18/26
  • Well LC1T03123.7 ug/L9/24/26
  • Well LC2T03922.6 ug/L12/10/25
  • Well LC1T00522 ug/L12/8/25
  • Well LC1T00919.6 ug/L9/15/26
  • Well LC1T00719.2 ug/L12/8/25
  • Well LC1T01617.4 ug/L9/22/26
  • Well LC1T0069.9 ug/L9/17/26
  • Well LC1T0019.8 ug/L12/5/25
  • Well LC1T0108.1 ug/L12/8/25
  • Well LC1T0207.2 ug/L9/17/26
  • Well LC2T0387.2 ug/L12/10/25
  • Well LC1T0036.5 ug/L9/16/26
  • Well LC1T0305.7 ug/L12/9/25
  • Well LC1T0124 ug/L9/16/26
  • Well LC1T0253.8 ug/L9/24/26
  • Well LC1T0343.7 ug/L12/9/25
  • Well LC1T0113.6 ug/L12/10/25
  • Well LC1T0353.4 ug/L12/9/25
  • Well LC1T0283.3 ug/L12/9/25
  • Well LC1T0043.2 ug/L9/18/26
  • Well LC3T0493.2 ug/L12/10/25
  • Well LC1T0273.1 ug/L12/9/25
  • Well LC1T0372.9 ug/L12/10/25
  • Well LC1T0222.9 ug/L12/9/25
  • Well LC1T0232.9 ug/L12/9/25
  • Well LC1T0262.9 ug/L12/9/25
  • Well LC1T0322.9 ug/L12/9/25
  • Well LC1T0292.8 ug/L12/9/25
  • Well LC1T0082.8 ug/L12/8/25
  • Well LC1T0362.7 ug/L12/10/25
  • Well LC1T0132.7 ug/L12/8/25
31.8ug/L3001300DNR
Toc7.3mg/L——DNR

Other Potential Contaminants

Not detecting a contaminant does not prove it isn't present — it only means the laboratory didn't test for it, or tested below the reporting limit. Many substances of emerging concern are not routinely monitored because federal regulations haven't caught up to the science.

Compliance History

Formal EPA and DNR compliance events on record for this utility. Includes all events from the last 10 years plus any unresolved violations regardless of age. Health-based violations are legally enforceable thresholds that were exceeded; procedural events are monitoring or reporting lapses that don't indicate contamination by themselves.

No EPA compliance events on record for this utility.

Source: EPA ECHO enforcement and violation records (via Envirofacts / SDWIS Federal Reports).

Routine Maintenance

Nothing in this system's current readings crosses a legal limit or a health guideline. Water systems still change over time, so the following is a baseline of habits worth keeping.

Frequently Asked Questions

What contaminants are in LITCHFIELD water?

Based on available public monitoring data, 39 contaminants have been tested in LITCHFIELD's water supply. 9 were detected above reporting limits. The most notable detections include Haloacetic Acids (HAA5), Total Trihalomethanes (TTHMs), Nitrate (as N). This data comes from source-level compliance monitoring at wells and treatment plants.

Does LITCHFIELD water meet EPA standards?

Based on available public monitoring data, 1 contaminant was measured above federal EPA standards in source-level monitoring. This does not necessarily indicate a formal violation — the EPA uses running averages and other criteria for compliance determinations. Data comes from wells and treatment plants, not tap-level measurements.

Is LITCHFIELD, IL water safe to drink?

Based on source-level compliance monitoring, 1 contaminant was measured above federal standards. However, compliance monitoring tests water at wells and treatment plants, not at individual taps. An on-site test is the only way to know what reaches your tap, as conditions can vary based on plumbing, blending, and distribution.

Does LITCHFIELD water have lead?

No. LITCHFIELD's most recent Lead and Copper Rule testing found a 90th-percentile lead level of 0.0091 mg/L, which is below the EPA action level of 0.015 mg/L. That means at the systemwide level, lead is not exceeding the enforcement threshold. Lead levels can still vary significantly by individual building — older homes and schools with legacy plumbing can have much higher readings than the system average.

Cross-check against the official record

This report is our read of the public monitoring data. Every Illinoisutility also publishes an annual Consumer Confidence Report (CCR) — a plain-language summary written by the utility itself, usually mailed with a water bill or posted on the utility's website. If anything in this report surprises you, request LITCHFIELD's latest CCR directly from the utility, or browse the underlying compliance data published by Illinois EPA.

Data Sources and Methodology

Illinois EPA Compliance Monitoring

State-level drinking water compliance testing. Covers all regulated contaminants for community water systems. Source-level monitoring at wells and treatment plants. Individual result links are provided for each contaminant in the tables above.

Water Quality Portal

Cooperative service by USGS, EPA, and NWQMC. Regional groundwater monitoring data from nearby wells — may not reflect this specific utility.

EPA ECHO Lead & Copper Rule

90th percentile measurements from EPA Enforcement and Compliance History Online. Based on tap-level sampling at high-risk sites.

EPA UCMR5

Unregulated Contaminant Monitoring Rule, Fifth cycle. Per-analyte PFAS results from utility-level sampling.

Definitions

Maximum Contaminant Level (MCL)
The highest level of a contaminant allowed in drinking water, set by the EPA. MCLs are legally enforceable standards.
Maximum Contaminant Level Goal (MCLG)
The level of a contaminant below which there is no known or expected health risk. MCLGs are non-enforceable public health goals.
Action Level
The concentration of a contaminant which, if exceeded, triggers treatment or other requirements. Used for lead and copper.
Health Advisory
Non-enforceable guidelines set by the EPA providing information on contaminants that can cause health effects at certain exposure levels.
Total Dissolved Solids (TDS)
A measure of all dissolved minerals, salts, and organic matter in water, expressed in mg/L (ppm). Not a health hazard but affects taste and indicates overall mineral content.
PFAS
Per- and polyfluoroalkyl substances. A group of manufactured chemicals that do not break down in the environment. The EPA set enforceable limits for several PFAS compounds in 2024.
Non-Detect (ND)
The contaminant was tested for but not found above the laboratory's reporting limit. This does not mean zero — it means below the detection threshold.
VOCs (Volatile Organic Compounds)
Chemicals that evaporate easily and can contaminate groundwater. Sources include gasoline, industrial solvents, and dry cleaning fluids. Some are regulated by the EPA; many are monitored but not yet regulated.

Download Data

Cite This Report

WaterAdvantage. "Water Quality Technical Report: LITCHFIELD, IL (IL1350400)." WaterAdvantage.org, 2026-11-01. https://www.wateradvantage.org/report/IL1350400/detail

Curious about filtration for your home or facility? I work at Bottleless Nation during the day and I'm happy to take a look. Submit the form below and I or a colleague will reach out — the consultation is free, and if it turns into a sale, I earn a commission.

Get a free filtration consultation