Skip to content

Water Quality Technical Report — ROUND LAKE, IL

PWSID
IL0971500
Population
18,430
Source
Surface Water
Data Period
—
Last Updated

A note from the author — I'm Jacob Thorwolf. WaterAdvantage.org is a personal project of mine, separate from my day job as an Account Executive at Bottleless Nation, a commercial water filtration company. If you request a consultation through any form on this site, it comes to me or a colleague at BN. More about this project →

Summary

ROUND LAKE serves approximately 18,430 people in ROUND LAKE, Illinois. Based on contaminant analyses from DNR, WQP, EPA ECHO, EPA UCMR5, 0 contaminants have been measured above federal EPA standards (MCL) and 1 exceeds health-based guidelines. The most significant finding is Lead (90th Percentile) at 0.0027 mg/L, which is 13.5x the health guideline. Data is drawn from source-level compliance monitoring and covers 2000 through 2026. Results reflect conditions at the point of collection (wells, treatment plants), not necessarily at the tap.

Key Findings

Understanding the two thresholds

EPA Legal Limit (MCL)

The highest level of a contaminant allowed by federal law. Utilities that exceed this threshold face enforcement action. Limits balance health risk against the cost of treatment, so they are not always set at levels considered safe by independent researchers.

Health Guideline

The level below which independent researchers (CalEPA, WHO, EWG) believe there is no known health risk. Guidelines are not legally enforceable but are typically stricter than legal limits — often by 10x or more for contaminants like arsenic and lead.

A reading can be below the EPA limit (legally compliant) while still exceeding health guidelines (above levels considered safe by independent researchers).

Exceeds Health Guidelines

These contaminants were detected below the EPA legal limit but above a health-based guideline from a public health agency (CalEPA OEHHA, WHO, or similar). Health guidelines are non-enforceable research-backed targets that are often stricter than the legal limit.

Detected contaminants
ContaminantResultUnitHealth GuidelineEPA Legal LimitSourceSample Date
Lead (90th Percentile)
Developmental delays in children, kidney damage, high blood pressure. There is no safe level of lead exposure.
2.7ug/L0.215
Pending rule: LCRI 2024 — Action level drops from 15 → 10 µg/L effective 2027; full lead service line replacement within 10 years (EPA Lead & Copper Rule Improvements, October 2024)
EPA ECHO

Microplastics

Microplastics have been documented in raw and treated drinking water worldwide, but federal regulations do not currently require testing — so there is no data specific to this system. Standardized methods and rules are in progress.

Other Regulated Contaminants

These contaminants were detected within federal standards (EPA Maximum Contaminant Levels). They are presented for transparency.

Total Trihalomethanes (TTHMs) (LRAA): 25.01 ug/L — within limit of 80 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2HT1, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Total Trihalomethanes (TTHMs) (LRAA): 24.65 ug/L — within limit of 80 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2DBP1, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Haloacetic Acids (HAA5) (LRAA): 9.06 ug/L — within limit of 60 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2HT1, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Haloacetic Acids (HAA5) (LRAA): 6.90 ug/L — within limit of 60 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2DBP1, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Detected contaminants
ContaminantResultUnitHealth GuidelineEPA Legal LimitSourceSample Date
Barium
Increase in blood pressure
59ug/L10002000DNR
Fluoride (natural)
Bone disease, mottled teeth in children
1.04mg/L44DNR
Combined Radium (226+228)
Increased risk of cancer
3.55pCi/L05DNR
Gross Alpha
Increased risk of cancer
8.66pCi/L015DNR
Arsenic
Skin damage, circulatory problems, increased risk of cancer
5.1ug/L0.00410WQP(3+ years ago)
Nitrate (as N)
Blue baby syndrome in infants
5.51mg/L1010(as N)WQP(5+ years ago)
Chromium (total)
Note: total chromium includes the harmless trivalent form (Cr-III). The toxic hexavalent form (Cr-VI) has no federal MCL; California set a 10 µg/L Cr-VI MCL in 2014.
Allergic dermatitis
1.2ug/L100100WQP(5+ years ago)

Unregulated Detected Contaminants

These contaminants were detected but do not have a federal Maximum Contaminant Level. They are monitored for awareness, not compliance.

Other Substances

Detected contaminants
ContaminantResultUnitHealth GuidelineEPA Legal LimitSourceSample Date
Copper (90th Percentile)
Gastrointestinal distress at high levels. Long-term exposure can cause liver or kidney damage.
Per-source breakdown (58 sampling locations)
  • Sampling locationMost recent valueSample date
  • Well LC5T057280 ug/L4/27/26
  • Well LC5T037240 ug/L4/20/26
  • Well LC3T025200 ug/L6/9/26
  • Well LC3T021200 ug/L10/14/25
  • Well LC5T041180 ug/L9/9/26
  • Well LC3T029170 ug/L9/25/26
  • Well LC3T024170 ug/L4/27/26
  • Well LC5T045150 ug/L9/10/26
  • Well LC5T054100 ug/L9/13/26
  • Well LC5T04484 ug/L9/10/26
  • Well LC3T03367 ug/L5/10/26
  • Well LC1T00362 ug/L9/9/26
  • Well LC5T03858 ug/L9/11/26
  • Well LC5T05255 ug/L9/11/26
  • Well LC5T06052 ug/L4/28/26
  • Well LC2T01345 ug/L4/27/26
  • Well LC1T00245 ug/L4/24/26
  • Well LC1T00843 ug/L5/27/26
  • Well LC5T04634 ug/L9/10/26
  • Well LC5T06832 ug/L5/19/26
  • Well LC1T01029 ug/L9/21/26
  • Well LC1T01129 ug/L4/28/26
  • Well LC3T02826 ug/L4/13/26
  • Well LC3T01625 ug/L4/7/26
  • Well LC5T04323 ug/L9/10/26
  • Well LC5T04222 ug/L9/11/26
  • Well LC5T04822 ug/L9/11/26
  • Well LC3T02621 ug/L9/10/26
  • Well LC1T00419 ug/L9/17/26
  • Well LC2T01417 ug/L9/24/26
  • Well LC5T04016 ug/L6/10/26
  • Well LC1T00716 ug/L4/7/26
  • Well LC5T05113 ug/L6/10/26
  • Well LC5T07112 ug/L6/10/26
  • Well LC5T05912 ug/L4/28/26
  • Well LC3T02711 ug/L9/22/26
  • Well LC5T05611 ug/L9/13/26
  • Well LC3T01811 ug/L5/20/26
  • Well LC3T01911 ug/L4/28/26
  • Well LC5T0479.1 ug/L9/24/26
  • Well LC5T0589.1 ug/L4/19/26
  • Well LC3T0358.5 ug/L9/14/26
  • Well LC3T0228.1 ug/L6/10/26
  • Well LC3T0238 ug/L4/15/26
  • Well LC1T0018 ug/L4/7/26
  • Well LC5T0637.8 ug/L9/10/26
  • Well LC3T0307.4 ug/L4/7/26
  • Well LC3T0347.1 ug/L5/19/26
  • Well LC1T0097.1 ug/L4/28/26
  • Well LC3T0177 ug/L4/28/26
  • Well LC1T0055.3 ug/L4/18/26
  • Well LC5T0705 ug/L4/27/26
  • Well LC3T0154.4 ug/L9/22/26
  • Well LC5T0624.4 ug/L9/14/26
  • Well LC5T0394.4 ug/L9/11/26
  • Well LC5T0533.6 ug/L4/10/26
  • Well LC3T0203.2 ug/L9/11/26
  • Well LC5T0503.1 ug/L5/6/26
170ug/L3001300DNR
Orthophosphate150ug/L——DNR

Other Potential Contaminants

Not detecting a contaminant does not prove it isn't present — it only means the laboratory didn't test for it, or tested below the reporting limit. Many substances of emerging concern are not routinely monitored because federal regulations haven't caught up to the science.

Compliance History

Formal EPA and DNR compliance events on record for this utility. Includes all events from the last 10 years plus any unresolved violations regardless of age. Health-based violations are legally enforceable thresholds that were exceeded; procedural events are monitoring or reporting lapses that don't indicate contamination by themselves.

No EPA compliance events on record for this utility.

Source: EPA ECHO enforcement and violation records (via Envirofacts / SDWIS Federal Reports).

Routine Maintenance

Nothing in this system's current readings crosses a legal limit or a health guideline. Water systems still change over time, so the following is a baseline of habits worth keeping.

Frequently Asked Questions

What contaminants are in ROUND LAKE water?

Based on available public monitoring data, 39 contaminants have been tested in ROUND LAKE's water supply. 9 were detected above reporting limits. The most notable detections include Haloacetic Acids (HAA5), Total Trihalomethanes (TTHMs), Barium. This data comes from source-level compliance monitoring at wells and treatment plants.

Does ROUND LAKE water meet EPA standards?

Based on available public monitoring data, no contaminants were measured above federal EPA standards in recent compliance monitoring. However, 1 contaminant exceeds independent health guidelines, which are often stricter than legal limits. This assessment is based on source-level monitoring data (wells and treatment plants), not tap-level measurements.

Is ROUND LAKE, IL water safe to drink?

Based on source-level compliance monitoring, all tested contaminants were within federal standards. However, compliance monitoring tests water at wells and treatment plants, not at individual taps. An on-site test is the only way to know what reaches your tap, as conditions can vary based on plumbing, blending, and distribution.

Does ROUND LAKE water have lead?

No. ROUND LAKE's most recent Lead and Copper Rule testing found a 90th-percentile lead level of 0.0027 mg/L, which is below the EPA action level of 0.015 mg/L. That means at the systemwide level, lead is not exceeding the enforcement threshold. Lead levels can still vary significantly by individual building — older homes and schools with legacy plumbing can have much higher readings than the system average.

Cross-check against the official record

This report is our read of the public monitoring data. Every Illinoisutility also publishes an annual Consumer Confidence Report (CCR) — a plain-language summary written by the utility itself, usually mailed with a water bill or posted on the utility's website. If anything in this report surprises you, request ROUND LAKE's latest CCR directly from the utility, or browse the underlying compliance data published by Illinois EPA.

Data Sources and Methodology

Illinois EPA Compliance Monitoring

State-level drinking water compliance testing. Covers all regulated contaminants for community water systems. Source-level monitoring at wells and treatment plants. Individual result links are provided for each contaminant in the tables above.

Water Quality Portal

Cooperative service by USGS, EPA, and NWQMC. Regional groundwater monitoring data from nearby wells — may not reflect this specific utility.

EPA ECHO Lead & Copper Rule

90th percentile measurements from EPA Enforcement and Compliance History Online. Based on tap-level sampling at high-risk sites.

EPA UCMR5

Unregulated Contaminant Monitoring Rule, Fifth cycle. Per-analyte PFAS results from utility-level sampling.

Definitions

Maximum Contaminant Level (MCL)
The highest level of a contaminant allowed in drinking water, set by the EPA. MCLs are legally enforceable standards.
Maximum Contaminant Level Goal (MCLG)
The level of a contaminant below which there is no known or expected health risk. MCLGs are non-enforceable public health goals.
Action Level
The concentration of a contaminant which, if exceeded, triggers treatment or other requirements. Used for lead and copper.
Health Advisory
Non-enforceable guidelines set by the EPA providing information on contaminants that can cause health effects at certain exposure levels.
Total Dissolved Solids (TDS)
A measure of all dissolved minerals, salts, and organic matter in water, expressed in mg/L (ppm). Not a health hazard but affects taste and indicates overall mineral content.
PFAS
Per- and polyfluoroalkyl substances. A group of manufactured chemicals that do not break down in the environment. The EPA set enforceable limits for several PFAS compounds in 2024.
Non-Detect (ND)
The contaminant was tested for but not found above the laboratory's reporting limit. This does not mean zero — it means below the detection threshold.
VOCs (Volatile Organic Compounds)
Chemicals that evaporate easily and can contaminate groundwater. Sources include gasoline, industrial solvents, and dry cleaning fluids. Some are regulated by the EPA; many are monitored but not yet regulated.

Download Data

Cite This Report

WaterAdvantage. "Water Quality Technical Report: ROUND LAKE, IL (IL0971500)." WaterAdvantage.org, 2026-11-01. https://www.wateradvantage.org/report/IL0971500/detail

Curious about filtration for your home or facility? I work at Bottleless Nation during the day and I'm happy to take a look. Submit the form below and I or a colleague will reach out — the consultation is free, and if it turns into a sale, I earn a commission.

Get a free filtration consultation