Skip to content

Water Quality Technical Report — MUNDELEIN, IL

PWSID
IL0971150
Population
31,500
Source
Surface Water
Data Period
—
Last Updated

A note from the author — I'm Jacob Thorwolf. WaterAdvantage.org is a personal project of mine, separate from my day job as an Account Executive at Bottleless Nation, a commercial water filtration company. If you request a consultation through any form on this site, it comes to me or a colleague at BN. More about this project →

Summary

MUNDELEIN serves approximately 31,500 people in MUNDELEIN, Illinois. Based on contaminant analyses from DNR, WQP, EPA ECHO, EPA UCMR5, 1 contaminant has been measured above federal EPA standards (MCL) and 2 exceed health-based guidelines. The most significant finding is Combined Radium (226+228) at 6.61 pCi/L, which is 1.3x the EPA legal limit. Data is drawn from source-level compliance monitoring and covers 2000 through 2026. Results reflect conditions at the point of collection (wells, treatment plants), not necessarily at the tap.

Key Findings

Understanding the two thresholds

EPA Legal Limit (MCL)

The highest level of a contaminant allowed by federal law. Utilities that exceed this threshold face enforcement action. Limits balance health risk against the cost of treatment, so they are not always set at levels considered safe by independent researchers.

Health Guideline

The level below which independent researchers (CalEPA, WHO, EWG) believe there is no known health risk. Guidelines are not legally enforceable but are typically stricter than legal limits — often by 10x or more for contaminants like arsenic and lead.

A reading can be below the EPA limit (legally compliant) while still exceeding health guidelines (above levels considered safe by independent researchers).

Exceeds Health Guidelines

These contaminants were detected below the EPA legal limit but above a health-based guideline from a public health agency (CalEPA OEHHA, WHO, or similar). Health guidelines are non-enforceable research-backed targets that are often stricter than the legal limit.

Detected contaminants
ContaminantResultUnitHealth GuidelineEPA Legal LimitSourceSample Date
Lead (90th Percentile)
Developmental delays in children, kidney damage, high blood pressure. There is no safe level of lead exposure.
4.3ug/L0.215
Pending rule: LCRI 2024 — Action level drops from 15 → 10 µg/L effective 2027; full lead service line replacement within 10 years (EPA Lead & Copper Rule Improvements, October 2024)
EPA ECHO

Microplastics

Microplastics have been documented in raw and treated drinking water worldwide, but federal regulations do not currently require testing — so there is no data specific to this system. Standardized methods and rules are in progress.

Other Regulated Contaminants

These contaminants were detected within federal standards (EPA Maximum Contaminant Levels). They are presented for transparency.

Total Trihalomethanes (TTHMs) (LRAA): 19.07 ug/L — within limit of 80 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2HH1, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Total Trihalomethanes (TTHMs) (LRAA): 15.03 ug/L — within limit of 80 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2DBP1, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Haloacetic Acids (HAA5) (LRAA): 7.09 ug/L — within limit of 60 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2HH1, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Haloacetic Acids (HAA5) (LRAA): 5.55 ug/L — within limit of 60 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2DBP1, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Detected contaminants
ContaminantResultUnitHealth GuidelineEPA Legal LimitSourceSample Date
Barium
Increase in blood pressure
41ug/L10002000DNR
Fluoride (natural)
Bone disease, mottled teeth in children
954ug/L40004000DNR
Gross Alpha
Increased risk of cancer
11.7pCi/L015DNR
Arsenic
Skin damage, circulatory problems, increased risk of cancer
5.1ug/L0.00410WQP(3+ years ago)
Nitrate (as N)
Blue baby syndrome in infants
5.51mg/L1010(as N)WQP(5+ years ago)
Chromium (total)
Note: total chromium includes the harmless trivalent form (Cr-III). The toxic hexavalent form (Cr-VI) has no federal MCL; California set a 10 µg/L Cr-VI MCL in 2014.
Allergic dermatitis
1.2ug/L100100WQP(5+ years ago)

Unregulated Detected Contaminants

These contaminants were detected but do not have a federal Maximum Contaminant Level. They are monitored for awareness, not compliance.

Other Substances

Detected contaminants
ContaminantResultUnitHealth GuidelineEPA Legal LimitSourceSample Date
Copper (90th Percentile)
Gastrointestinal distress at high levels. Long-term exposure can cause liver or kidney damage.
Per-source breakdown (63 sampling locations)
  • Sampling locationMost recent valueSample date
  • Well LC3T098290 ug/L9/1/26
  • Well LC1T030190 ug/L10/31/25
  • Well LC1T032160 ug/L6/19/26
  • Well LC1T041150 ug/L8/3/26
  • Well LC3T055120 ug/L7/2/26
  • Well LC1T00786 ug/L6/30/26
  • Well LC1T01864 ug/L7/23/26
  • Well LC3T10149 ug/L9/2/26
  • Well LC3T05848 ug/L7/7/26
  • Well LC3T10047 ug/L9/2/26
  • Well LC1T00345 ug/L6/22/26
  • Well LC1T02543 ug/L6/26/26
  • Well LC4T02943 ug/L9/5/25
  • Well LC3T10339 ug/L9/1/26
  • Well LC4T01536 ug/L9/9/25
  • Well LC1T01732 ug/L9/2/25
  • Well LC3T09425 ug/L9/1/26
  • Well LC3T06324 ug/L7/9/26
  • Well LC3T05221 ug/L7/31/26
  • Well LC3T05320 ug/L7/9/26
  • Well LC1T01619 ug/L7/31/26
  • Well LC5T03419 ug/L7/28/26
  • Well LC3T07919 ug/L7/23/26
  • Well LC1T03619 ug/L6/18/26
  • Well LC3T09618 ug/L9/1/26
  • Well LC3T06917 ug/L7/24/26
  • Well LC1T07117 ug/L7/23/26
  • Well LC3T07316 ug/L7/23/26
  • Well LC1T02616 ug/L7/14/26
  • Well LC3T07815 ug/L7/28/26
  • Well LC5T04615 ug/L9/2/25
  • Well LC3T06614 ug/L7/25/26
  • Well LC3T06014 ug/L6/26/26
  • Well LC3T09213 ug/L9/7/26
  • Well LC3T05713 ug/L7/1/26
  • Well LC3T10212 ug/L8/31/26
  • Well LC3T08012 ug/L7/23/26
  • Well LC3T08212 ug/L7/23/26
  • Well LC1T02812 ug/L7/3/26
  • Well LC1T01312 ug/L6/23/26
  • Well LC4T00512 ug/L9/1/25
  • Well LC1T07211 ug/L8/17/26
  • Well LC1T0089.2 ug/L7/8/26
  • Well LC3T0839.1 ug/L9/1/26
  • Well LC3T0938.1 ug/L9/1/26
  • Well LC3T0687.9 ug/L7/23/26
  • Well LC3T0757.9 ug/L7/22/26
  • Well LC1T0067.8 ug/L7/10/26
  • Well LC3T0847.7 ug/L7/22/26
  • Well LC3T0776.7 ug/L7/22/26
  • Well LC1T0146.7 ug/L6/18/26
  • Well LC3T0546.6 ug/L7/2/26
  • Well LC1T0016.4 ug/L6/17/26
  • Well LC3T0516.1 ug/L7/8/26
  • Well LC1T0405.7 ug/L6/18/26
  • Well LC1T0095.6 ug/L6/18/26
  • Well LC1T0335.2 ug/L9/14/25
  • Well LC1T0024 ug/L7/23/26
  • Well LC3T0903.9 ug/L7/30/26
  • Well LC3T0593.6 ug/L7/9/26
  • Well LC3T0813.4 ug/L8/17/26
  • Well LC3T0483.2 ug/L7/28/26
  • Well LC3T0913.2 ug/L7/22/26
13ug/L3001300DNR
Orthophosphate130ug/L——DNR

Other Potential Contaminants

Not detecting a contaminant does not prove it isn't present — it only means the laboratory didn't test for it, or tested below the reporting limit. Many substances of emerging concern are not routinely monitored because federal regulations haven't caught up to the science.

Compliance History

Formal EPA and DNR compliance events on record for this utility. Includes all events from the last 10 years plus any unresolved violations regardless of age. Health-based violations are legally enforceable thresholds that were exceeded; procedural events are monitoring or reporting lapses that don't indicate contamination by themselves.

0 health-based5 procedural
Total Trihalomethanes (TTHMs)
Consumer Confidence Report

Jan 1, 2024 – Mar 31, 2024

Haloacetic Acids (HAA5)
Consumer Confidence Report

Jan 1, 2024 – Mar 31, 2024

Total Coliform (RTCR)
Monitoring (Unresolved)

Jul 1, 2011 – ongoing

Total Coliform (RTCR)
Monitoring (Unresolved)

Jul 1, 2007 – ongoing

E. coli (RTCR)
Administrative

Sep 11, 2004 – ongoing

Source: EPA ECHO enforcement and violation records (via Envirofacts / SDWIS Federal Reports).

Action Steps

This system has contaminants above a legal limit or multiple health guidelines. The following steps are concrete things a homeowner or facility operator can do right now — starting with the most important non-commercial options.

  1. Request the utility's Consumer Confidence Report (CCR). The CCR compares utility-reported readings to the federal legal limits and is independent of this site. Utilities must make it available on request. EPA CCR search.
  2. Get a certified tap test. A state-certified laboratory can test your tap for a specific contaminant or a broader panel. A single-contaminant test runs in the low tens of dollars; a comprehensive panel runs several hundred. Ask for the EPA-certified lab list from the Illinois drinking water program. State lab certification programs.
  3. Consider point-of-use filtration. For the specific contaminants detected in this system, the exceedance sections above list the technology categories (reverse osmosis, granular activated carbon, ion exchange, etc.) that target each class. Those are category-level descriptions — the right choice depends on the contaminant profile, budget, and installation constraints.
  4. Contact the utility directly. Ask about the specific contaminants you're concerned about and request the most recent sampling data. The EPA SDWIS portal lists utility contact details. EPA SDWIS system lookup.
  5. Check the utility's lead service line inventory. Under the Lead and Copper Rule Revisions (LCRR, 2024), utilities must publish a service line inventory identifying lines flagged as lead, galvanized-requiring-replacement, or unknown material. If your service line is flagged or unknown, the utility is required to replace it on a scheduled timeline. EPA Lead and Copper Rule Improvements.

Frequently Asked Questions

What contaminants are in MUNDELEIN water?

Based on available public monitoring data, 39 contaminants have been tested in MUNDELEIN's water supply. 9 were detected above reporting limits. The most notable detections include Haloacetic Acids (HAA5), Total Trihalomethanes (TTHMs), Barium. This data comes from source-level compliance monitoring at wells and treatment plants.

Does MUNDELEIN water meet EPA standards?

Based on available public monitoring data, 1 contaminant was measured above federal EPA standards in source-level monitoring. This does not necessarily indicate a formal violation — the EPA uses running averages and other criteria for compliance determinations. Data comes from wells and treatment plants, not tap-level measurements.

Is MUNDELEIN, IL water safe to drink?

Based on source-level compliance monitoring, 1 contaminant was measured above federal standards. However, compliance monitoring tests water at wells and treatment plants, not at individual taps. An on-site test is the only way to know what reaches your tap, as conditions can vary based on plumbing, blending, and distribution.

Does MUNDELEIN water have lead?

No. MUNDELEIN's most recent Lead and Copper Rule testing found a 90th-percentile lead level of 0.0043 mg/L, which is below the EPA action level of 0.015 mg/L. That means at the systemwide level, lead is not exceeding the enforcement threshold. Lead levels can still vary significantly by individual building — older homes and schools with legacy plumbing can have much higher readings than the system average.

Cross-check against the official record

This report is our read of the public monitoring data. Every Illinoisutility also publishes an annual Consumer Confidence Report (CCR) — a plain-language summary written by the utility itself, usually mailed with a water bill or posted on the utility's website. If anything in this report surprises you, request MUNDELEIN's latest CCR directly from the utility, or browse the underlying compliance data published by Illinois EPA.

Data Sources and Methodology

Illinois EPA Compliance Monitoring

State-level drinking water compliance testing. Covers all regulated contaminants for community water systems. Source-level monitoring at wells and treatment plants. Individual result links are provided for each contaminant in the tables above.

Water Quality Portal

Cooperative service by USGS, EPA, and NWQMC. Regional groundwater monitoring data from nearby wells — may not reflect this specific utility.

EPA ECHO Lead & Copper Rule

90th percentile measurements from EPA Enforcement and Compliance History Online. Based on tap-level sampling at high-risk sites.

EPA UCMR5

Unregulated Contaminant Monitoring Rule, Fifth cycle. Per-analyte PFAS results from utility-level sampling.

Definitions

Maximum Contaminant Level (MCL)
The highest level of a contaminant allowed in drinking water, set by the EPA. MCLs are legally enforceable standards.
Maximum Contaminant Level Goal (MCLG)
The level of a contaminant below which there is no known or expected health risk. MCLGs are non-enforceable public health goals.
Action Level
The concentration of a contaminant which, if exceeded, triggers treatment or other requirements. Used for lead and copper.
Health Advisory
Non-enforceable guidelines set by the EPA providing information on contaminants that can cause health effects at certain exposure levels.
Total Dissolved Solids (TDS)
A measure of all dissolved minerals, salts, and organic matter in water, expressed in mg/L (ppm). Not a health hazard but affects taste and indicates overall mineral content.
PFAS
Per- and polyfluoroalkyl substances. A group of manufactured chemicals that do not break down in the environment. The EPA set enforceable limits for several PFAS compounds in 2024.
Non-Detect (ND)
The contaminant was tested for but not found above the laboratory's reporting limit. This does not mean zero — it means below the detection threshold.
VOCs (Volatile Organic Compounds)
Chemicals that evaporate easily and can contaminate groundwater. Sources include gasoline, industrial solvents, and dry cleaning fluids. Some are regulated by the EPA; many are monitored but not yet regulated.

Download Data

Cite This Report

WaterAdvantage. "Water Quality Technical Report: MUNDELEIN, IL (IL0971150)." WaterAdvantage.org, 2026-11-01. https://www.wateradvantage.org/report/IL0971150/detail

Curious about filtration for your home or facility? I work at Bottleless Nation during the day and I'm happy to take a look. Submit the form below and I or a colleague will reach out — the consultation is free, and if it turns into a sale, I earn a commission.

Get a free filtration consultation