Skip to content

Water Quality Technical Report — CANTON, IL

PWSID
IL0570250
Population
16,748
Source
Surface Water
Data Period
—
Last Updated

A note from the author — I'm Jacob Thorwolf. WaterAdvantage.org is a personal project of mine, separate from my day job as an Account Executive at Bottleless Nation, a commercial water filtration company. If you request a consultation through any form on this site, it comes to me or a colleague at BN. More about this project →

Summary

CANTON serves approximately 16,748 people in CANTON, Illinois. Based on contaminant analyses from DNR, WQP, EPA ECHO, EPA UCMR5, 0 contaminants have been measured above federal EPA standards (MCL) and 3 exceed health-based guidelines. The most significant finding is Lead (90th Percentile) at 0.0024 mg/L, which is 12x the health guideline. Data is drawn from source-level compliance monitoring and covers 1996 through 2028. Results reflect conditions at the point of collection (wells, treatment plants), not necessarily at the tap.

Key Findings

Understanding the two thresholds

EPA Legal Limit (MCL)

The highest level of a contaminant allowed by federal law. Utilities that exceed this threshold face enforcement action. Limits balance health risk against the cost of treatment, so they are not always set at levels considered safe by independent researchers.

Health Guideline

The level below which independent researchers (CalEPA, WHO, EWG) believe there is no known health risk. Guidelines are not legally enforceable but are typically stricter than legal limits — often by 10x or more for contaminants like arsenic and lead.

A reading can be below the EPA limit (legally compliant) while still exceeding health guidelines (above levels considered safe by independent researchers).

Exceeds Health Guidelines

These contaminants were detected below the EPA legal limit but above a health-based guideline from a public health agency (CalEPA OEHHA, WHO, or similar). Health guidelines are non-enforceable research-backed targets that are often stricter than the legal limit.

Detected contaminants
ContaminantResultUnitHealth GuidelineEPA Legal LimitSourceSample Date
Arsenic
Skin damage, circulatory problems, increased risk of cancer
3.5ug/L0.00410DNR
Lead (90th Percentile)
Developmental delays in children, kidney damage, high blood pressure. There is no safe level of lead exposure.
2.4ug/L0.215
Pending rule: LCRI 2024 — Action level drops from 15 → 10 µg/L effective 2027; full lead service line replacement within 10 years (EPA Lead & Copper Rule Improvements, October 2024)
EPA ECHO
Atrazine
Cardiovascular system or reproductive problems
1.3ug/L0.153DNR

PFAS

Per- and polyfluoroalkyl substances (PFAS) are a group of manufactured chemicals that persist in the environment and accumulate in the human body. The EPA set enforceable limits for six PFAS compounds in April 2024, with a compliance deadline of 2029. PFAS compounds measured above EPA standards appear in the Above Federal Standard section above.

Detected contaminants
ContaminantResultUnitHealth GuidelineEPA Legal LimitSourceSample Date
PFBA (Perfluorobutanoic Acid)
Shorter-chain PFAS with faster elimination. Thyroid effects in animal studies.
8.3ng/LNot publishedNot regulatedEPA UCMR5(17 months ago)
Pfhxa3ng/L——EPA UCMR5(17 months ago)
Pfpea3.5ng/L——EPA UCMR5(17 months ago)

Microplastics

Microplastics have been documented in raw and treated drinking water worldwide, but federal regulations do not currently require testing — so there is no data specific to this system. Standardized methods and rules are in progress.

Other Regulated Contaminants

These contaminants were detected within federal standards (EPA Maximum Contaminant Levels). They are presented for transparency.

Total Trihalomethanes (TTHMs) (LRAA): 31.58 ug/L — within limit of 80 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2DBP1, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Total Trihalomethanes (TTHMs) (LRAA): 30.08 ug/L — within limit of 80 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2HH1, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Total Trihalomethanes (TTHMs) (LRAA): 26.90 ug/L — within limit of 80 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2HT2, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Total Trihalomethanes (TTHMs) (LRAA): 26.62 ug/L — within limit of 80 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2HT1, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Haloacetic Acids (HAA5) (LRAA): 17.64 ug/L — within limit of 60 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2DBP1, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Haloacetic Acids (HAA5) (LRAA): 14.99 ug/L — within limit of 60 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2HT2, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Haloacetic Acids (HAA5) (LRAA): 14.97 ug/L — within limit of 60 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2HH1, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Haloacetic Acids (HAA5) (LRAA): 13.84 ug/L — within limit of 60 ug/L

EPA Stage 2 DBPR — Locational Running Annual Average, monitoring point Well S2HT1, based on 4 samples across 4 quarters (2025Q4 · 2026Q1 · 2026Q2 · 2026Q3).

Disinfection byproducts are regulated as a running average under Stage 2 DBPR, not as individual samples. A single sample exceeding the MCL is not itself a compliance violation — the annual running average is the enforceable metric.

Detected contaminants
ContaminantResultUnitHealth GuidelineEPA Legal LimitSourceSample Date
Barium
Increase in blood pressure
99ug/L10002000DNR
Fluoride (natural)
Bone disease, mottled teeth in children
590ug/L40004000DNR
Nitrate (as N)
Blue baby syndrome in infants
2.39mg/L1010(as N)WQP(3+ years ago)
Chromium (total)
Note: total chromium includes the harmless trivalent form (Cr-III). The toxic hexavalent form (Cr-VI) has no federal MCL; California set a 10 µg/L Cr-VI MCL in 2014.
Allergic dermatitis
7ug/L100100WQP(30+ years ago)

Unregulated Detected Contaminants

These contaminants were detected but do not have a federal Maximum Contaminant Level. They are monitored for awareness, not compliance.

Other Substances

Detected contaminants
ContaminantResultUnitHealth GuidelineEPA Legal LimitSourceSample Date
Toc5.8mg/L——DNR
Copper (90th Percentile)
Gastrointestinal distress at high levels. Long-term exposure can cause liver or kidney damage.
Per-source breakdown (56 sampling locations)
  • Sampling locationMost recent valueSample date
  • Well LC1T135170 ug/L10/2/25
  • Well LC1T037140 ug/L10/1/25
  • Well LC1T02287 ug/L9/30/25
  • Well LC1T11759 ug/L10/8/25
  • Well LC1T18449 ug/L7/27/26
  • Well LC1T14143 ug/L9/30/25
  • Well LC1T02339 ug/L10/8/25
  • Well LC1T15536 ug/L10/9/25
  • Well LC1T12736 ug/L9/30/25
  • Well LC1T05335 ug/L11/18/25
  • Well LC5T10334 ug/L10/8/25
  • Well LC1T19333 ug/L7/20/26
  • Well LC1T11533 ug/L9/29/25
  • Well LC1T20732 ug/L7/29/26
  • Well LC1T16322 ug/L7/22/26
  • Well LC1T13322 ug/L10/3/25
  • Well LC1T13921 ug/L10/27/25
  • Well LC1T24119 ug/L7/15/26
  • Well LC1T14818 ug/L10/8/25
  • Well LC1T02017 ug/L10/9/25
  • Well LC1T19115 ug/L6/30/26
  • Well LC1T07215 ug/L11/19/25
  • Well LC1T01915 ug/L9/19/25
  • Well LC1T13214 ug/L9/30/25
  • Well LC1T24512 ug/L7/22/26
  • Well LC1T15812 ug/L10/13/25
  • Well LC1T01111 ug/L8/4/26
  • Well LC1T18711 ug/L7/28/26
  • Well LC1T18811 ug/L7/24/26
  • Well LC1T15911 ug/L9/24/25
  • Well LC1T17910 ug/L7/23/26
  • Well LC1T1729.8 ug/L7/17/26
  • Well LC1T1189.7 ug/L7/29/26
  • Well LC2T0879.1 ug/L12/3/25
  • Well LC1T1989 ug/L6/30/26
  • Well LC1T0499 ug/L11/18/25
  • Well LC1T0638.5 ug/L12/2/25
  • Well LC1T0488.1 ug/L11/18/25
  • Well LC1T2097.7 ug/L8/13/26
  • Well LC1T0506.5 ug/L11/19/25
  • Well LC1T1285.9 ug/L10/1/25
  • Well LC1T0665.7 ug/L11/28/25
  • Well LC1T1605.4 ug/L10/7/25
  • Well LC1T0215.4 ug/L10/2/25
  • Well LC1T2825.3 ug/L7/16/26
  • Well LC1T1165.3 ug/L10/1/25
  • Well LC1T0165 ug/L9/29/25
  • Well LC1T0604.9 ug/L11/18/25
  • Well LC1T1374.9 ug/L10/2/25
  • Well LC1T2944.4 ug/L7/29/26
  • Well LC1T0324.4 ug/L10/2/25
  • Well LC1T0574.3 ug/L11/19/25
  • Well LC1T0344.2 ug/L10/2/25
  • Well LC1T1974 ug/L7/26/26
  • Well LC1T1233.8 ug/L8/12/26
  • Well LC1T2753 ug/L8/6/26
7.7ug/L3001300DNR
Toluene500ng/L——DNR

Other Potential Contaminants

Not detecting a contaminant does not prove it isn't present — it only means the laboratory didn't test for it, or tested below the reporting limit. Many substances of emerging concern are not routinely monitored because federal regulations haven't caught up to the science.

Compliance History

Formal EPA and DNR compliance events on record for this utility. Includes all events from the last 10 years plus any unresolved violations regardless of age. Health-based violations are legally enforceable thresholds that were exceeded; procedural events are monitoring or reporting lapses that don't indicate contamination by themselves.

No EPA compliance events on record for this utility.

Source: EPA ECHO enforcement and violation records (via Envirofacts / SDWIS Federal Reports).

Action Steps

This system has contaminants above a legal limit or multiple health guidelines. The following steps are concrete things a homeowner or facility operator can do right now — starting with the most important non-commercial options.

  1. Request the utility's Consumer Confidence Report (CCR). The CCR compares utility-reported readings to the federal legal limits and is independent of this site. Utilities must make it available on request. EPA CCR search.
  2. Get a certified tap test. A state-certified laboratory can test your tap for a specific contaminant or a broader panel. A single-contaminant test runs in the low tens of dollars; a comprehensive panel runs several hundred. Ask for the EPA-certified lab list from the Illinois drinking water program. State lab certification programs.
  3. Consider point-of-use filtration. For the specific contaminants detected in this system, the exceedance sections above list the technology categories (reverse osmosis, granular activated carbon, ion exchange, etc.) that target each class. Those are category-level descriptions — the right choice depends on the contaminant profile, budget, and installation constraints.
  4. Contact the utility directly. Ask about the specific contaminants you're concerned about and request the most recent sampling data. The EPA SDWIS portal lists utility contact details. EPA SDWIS system lookup.
  5. Check the utility's lead service line inventory. Under the Lead and Copper Rule Revisions (LCRR, 2024), utilities must publish a service line inventory identifying lines flagged as lead, galvanized-requiring-replacement, or unknown material. If your service line is flagged or unknown, the utility is required to replace it on a scheduled timeline. EPA Lead and Copper Rule Improvements.

Frequently Asked Questions

What contaminants are in CANTON water?

Based on available public monitoring data, 40 contaminants have been tested in CANTON's water supply. 13 were detected above reporting limits. The most notable detections include Haloacetic Acids (HAA5), Total Trihalomethanes (TTHMs), Arsenic. This data comes from source-level compliance monitoring at wells and treatment plants.

Does CANTON water meet EPA standards?

Based on available public monitoring data, no contaminants were measured above federal EPA standards in recent compliance monitoring. However, 3 contaminants exceed independent health guidelines, which are often stricter than legal limits. This assessment is based on source-level monitoring data (wells and treatment plants), not tap-level measurements.

Is CANTON, IL water safe to drink?

Based on source-level compliance monitoring, all tested contaminants were within federal standards. However, compliance monitoring tests water at wells and treatment plants, not at individual taps. An on-site test is the only way to know what reaches your tap, as conditions can vary based on plumbing, blending, and distribution.

Does CANTON water have PFAS?

Yes, PFAS compounds have been detected in source monitoring for CANTON's water supply: PFBA (Perfluorobutanoic Acid) (0.0083 ug/L), Pfpea (0.0035 ug/L), Pfhxa (0.003 ug/L). PFAS are a group of manufactured chemicals that do not break down in the environment. The EPA set enforceable limits for several PFAS compounds in 2024.

Does CANTON water have lead?

No. CANTON's most recent Lead and Copper Rule testing found a 90th-percentile lead level of 0.0024 mg/L, which is below the EPA action level of 0.015 mg/L. That means at the systemwide level, lead is not exceeding the enforcement threshold. Lead levels can still vary significantly by individual building — older homes and schools with legacy plumbing can have much higher readings than the system average.

Cross-check against the official record

This report is our read of the public monitoring data. Every Illinoisutility also publishes an annual Consumer Confidence Report (CCR) — a plain-language summary written by the utility itself, usually mailed with a water bill or posted on the utility's website. If anything in this report surprises you, request CANTON's latest CCR directly from the utility, or browse the underlying compliance data published by Illinois EPA.

Data Sources and Methodology

Illinois EPA Compliance Monitoring

State-level drinking water compliance testing. Covers all regulated contaminants for community water systems. Source-level monitoring at wells and treatment plants. Individual result links are provided for each contaminant in the tables above.

Water Quality Portal

Cooperative service by USGS, EPA, and NWQMC. Regional groundwater monitoring data from nearby wells — may not reflect this specific utility.

EPA ECHO Lead & Copper Rule

90th percentile measurements from EPA Enforcement and Compliance History Online. Based on tap-level sampling at high-risk sites.

EPA UCMR5

Unregulated Contaminant Monitoring Rule, Fifth cycle. Per-analyte PFAS results from utility-level sampling.

Definitions

Maximum Contaminant Level (MCL)
The highest level of a contaminant allowed in drinking water, set by the EPA. MCLs are legally enforceable standards.
Maximum Contaminant Level Goal (MCLG)
The level of a contaminant below which there is no known or expected health risk. MCLGs are non-enforceable public health goals.
Action Level
The concentration of a contaminant which, if exceeded, triggers treatment or other requirements. Used for lead and copper.
Health Advisory
Non-enforceable guidelines set by the EPA providing information on contaminants that can cause health effects at certain exposure levels.
Total Dissolved Solids (TDS)
A measure of all dissolved minerals, salts, and organic matter in water, expressed in mg/L (ppm). Not a health hazard but affects taste and indicates overall mineral content.
PFAS
Per- and polyfluoroalkyl substances. A group of manufactured chemicals that do not break down in the environment. The EPA set enforceable limits for several PFAS compounds in 2024.
Non-Detect (ND)
The contaminant was tested for but not found above the laboratory's reporting limit. This does not mean zero — it means below the detection threshold.
VOCs (Volatile Organic Compounds)
Chemicals that evaporate easily and can contaminate groundwater. Sources include gasoline, industrial solvents, and dry cleaning fluids. Some are regulated by the EPA; many are monitored but not yet regulated.

Download Data

Cite This Report

WaterAdvantage. "Water Quality Technical Report: CANTON, IL (IL0570250)." WaterAdvantage.org, 2026-11-01. https://www.wateradvantage.org/report/IL0570250/detail

Curious about filtration for your home or facility? I work at Bottleless Nation during the day and I'm happy to take a look. Submit the form below and I or a colleague will reach out — the consultation is free, and if it turns into a sale, I earn a commission.

Get a free filtration consultation