{"schema_version":"1.2","pwsid":"MN1860013","system_name":"The Meadows","city":"Monticello","state":"MN","population_served":1000,"source_type":"GW","summary":"The Meadows serves approximately 1,000 people in Monticello, Minnesota. Based on contaminant analyses from DNR, WQP, EPA ECHO, the most recent monitoring readings are within federal EPA standards (MCL), but this system has active MCL violations on record for 1 contaminant. 2 contaminants exceed health-based guidelines. The most significant finding is Lead (90th Percentile) at 0.001 mg/L, which is 5x the health guideline. Data is drawn from source-level compliance monitoring and covers 1996 through 2026. Results reflect conditions at the point of collection (wells, treatment plants), not necessarily at the tap.","data_period":{"start":"1996-05-28","end":"2026-10-08"},"contaminants_tested":5,"contaminants_detected":5,"exceedances":0,"guideline_exceedances":2,"contaminants":[{"name":"PFBA (Perfluorobutanoic Acid)","code":"PFBA","cas_number":null,"group":"pfas","section":"other_detected","measured_value":4.4,"unit":"ng/L","sample_date":"2026-10-08","source":"DNR","source_scope":"source_monitoring","health_guideline_value":null,"health_guideline_source":null,"epa_mcl_value":null,"status":"detected","detection_limit":null},{"name":"Nitrate (as N)","code":"NITRATE","cas_number":"14797-55-8","group":"inorganics","section":"other_detected","measured_value":9.5,"unit":"mg/L","sample_date":"2025-12-31","source":"DNR","source_scope":"source_monitoring","health_guideline_value":10,"health_guideline_source":"EPA MCLG","epa_mcl_value":10,"status":"approaching","detection_limit":null},{"name":"Tetrachloroethylene (PCE)","code":"2987","cas_number":null,"group":"vocs","section":"guideline_exceedance","measured_value":0.1,"unit":"ug/L","sample_date":"2025-12-31","source":"DNR","source_scope":"source_monitoring","health_guideline_value":0.00006,"health_guideline_source":"OEHHA PHG","epa_mcl_value":0.005,"status":"exceeds_guideline","detection_limit":null},{"name":"Trichloroethylene (TCE)","code":"2984","cas_number":null,"group":"vocs","section":"other_detected","measured_value":0.05,"unit":"ug/L","sample_date":"2025-12-31","source":"DNR","source_scope":"source_monitoring","health_guideline_value":0.0017,"health_guideline_source":"OEHHA PHG","epa_mcl_value":0.005,"status":"below_limits","detection_limit":null},{"name":"Arsenic","code":"ARSENIC","cas_number":"7440-38-2","group":"inorganics","section":"other_detected","measured_value":3.28,"unit":"ug/L","sample_date":"2025-08-06","source":"WQP","source_scope":"regional_groundwater","health_guideline_value":0.000004,"health_guideline_source":"OEHHA PHG","epa_mcl_value":0.01,"status":"exceeds_guideline","detection_limit":null},{"name":"Barium","code":"BARIUM","cas_number":"7440-39-3","group":"inorganics","section":"other_detected","measured_value":0.0678,"unit":"mg/L","sample_date":"2025-08-14","source":"WQP","source_scope":"regional_groundwater","health_guideline_value":1,"health_guideline_source":"OEHHA PHG 2003 (hypertension endpoint)","epa_mcl_value":2,"status":"below_limits","detection_limit":null},{"name":"Chromium (total)","code":"CHROMIUM","cas_number":"7440-47-3","group":"inorganics","section":"other_detected","measured_value":29.1,"unit":"ug/L","sample_date":"2025-08-14","source":"WQP","source_scope":"regional_groundwater","health_guideline_value":0.1,"health_guideline_source":"EPA MCLG","epa_mcl_value":0.1,"status":"below_limits","detection_limit":null},{"name":"Fluoride (natural)","code":"FLUORIDE","cas_number":"16984-48-8","group":"inorganics","section":"other_detected","measured_value":0.24,"unit":"mg/L","sample_date":"2025-07-17","source":"WQP","source_scope":"regional_groundwater","health_guideline_value":4,"health_guideline_source":"EPA MCLG","epa_mcl_value":4,"status":"below_limits","detection_limit":null},{"name":"Lead (90th Percentile)","code":"PB90","cas_number":"7439-92-1","group":"lead_copper","section":"guideline_exceedance","measured_value":0.001,"unit":"mg/L","sample_date":"2023-12-31","source":"EPA ECHO","source_scope":"federal_program","health_guideline_value":0.0002,"health_guideline_source":"OEHHA PHG","epa_mcl_value":null,"status":"exceeds_guideline","detection_limit":null},{"name":"Copper (90th Percentile)","code":"COPPER","cas_number":"7440-50-8","group":"lead_copper","section":"other_detected","measured_value":27.6,"unit":"ug/L","sample_date":"2023-06-29","source":"WQP","source_scope":"regional_groundwater","health_guideline_value":0.3,"health_guideline_source":"OEHHA PHG","epa_mcl_value":null,"status":"below_limits","detection_limit":null}],"sources":[{"name":"DNR","url":"https://apps.dnr.wi.gov/dwsportalpub"},{"name":"WQP","url":"https://www.waterqualitydata.us/"},{"name":"EPA ECHO","url":"https://echo.epa.gov/"}],"pfas_combined_display":null,"well_counts":{"active":7,"retired":1,"facilities_synced_at":"2026-10-26T01:03:17.192Z"},"historical_wells":[],"has_only_historical_data":false,"pfas_hazard_index":null,"tthm_lraa":[],"haa5_lraa":[]}