{"schema_version":"1.2","pwsid":"IL0317765","system_name":"BLACKHAWK ESTATES LLC","city":"CHICAGO","state":"IL","population_served":1238,"source_type":"GW","summary":"BLACKHAWK ESTATES LLC serves approximately 1,238 people in CHICAGO, Illinois. Based on contaminant analyses from DNR, WQP, EPA ECHO, the most recent monitoring readings are within federal EPA standards (MCL), but this system has active MCL violations on record for 1 contaminant. 0 contaminants exceed health-based guidelines. Data is drawn from source-level compliance monitoring and covers 2007 through 2026. Results reflect conditions at the point of collection (wells, treatment plants), not necessarily at the tap.","data_period":{"start":"2007-10-09","end":"2026-09-03"},"contaminants_tested":6,"contaminants_detected":6,"exceedances":0,"guideline_exceedances":0,"contaminants":[{"name":"Total Trihalomethanes (TTHMs)","code":"2950","cas_number":null,"group":"dbps","section":"other_detected","measured_value":5.65,"unit":"ug/L","sample_date":"2026-09-03","source":"DNR","source_scope":"source_monitoring","health_guideline_value":0.00015,"health_guideline_source":"EWG Health Guideline","epa_mcl_value":0.08,"status":"below_limits","detection_limit":null},{"name":"Combined Radium (226+228)","code":"4010","cas_number":null,"group":"radionuclides","section":"other_detected","measured_value":2.093,"unit":"pCi/L","sample_date":"2026-08-18","source":"DNR","source_scope":"source_monitoring","health_guideline_value":0,"health_guideline_source":"EPA MCLG","epa_mcl_value":5,"status":"below_limits","detection_limit":null},{"name":"Gross Alpha","code":"4000","cas_number":null,"group":"radionuclides","section":"other_detected","measured_value":4.03,"unit":"pCi/L","sample_date":"2026-08-18","source":"DNR","source_scope":"source_monitoring","health_guideline_value":0,"health_guideline_source":"EPA MCLG","epa_mcl_value":15,"status":"below_limits","detection_limit":null},{"name":"Barium","code":"BARIUM","cas_number":"7440-39-3","group":"inorganics","section":"other_detected","measured_value":0.011,"unit":"mg/L","sample_date":"2026-03-20","source":"DNR","source_scope":"source_monitoring","health_guideline_value":1,"health_guideline_source":"OEHHA PHG 2003 (hypertension endpoint)","epa_mcl_value":2,"status":"below_limits","detection_limit":null},{"name":"Fluoride (natural)","code":"FLUORIDE","cas_number":"16984-48-8","group":"inorganics","section":"other_detected","measured_value":0.902,"unit":"mg/L","sample_date":"2026-03-20","source":"DNR","source_scope":"source_monitoring","health_guideline_value":4,"health_guideline_source":"EPA MCLG","epa_mcl_value":4,"status":"below_limits","detection_limit":null},{"name":"Arsenic","code":"ARSENIC","cas_number":"7440-38-2","group":"inorganics","section":"other_detected","measured_value":0.17,"unit":"ug/L","sample_date":"2014-07-21","source":"WQP","source_scope":"regional_groundwater","health_guideline_value":0.000004,"health_guideline_source":"OEHHA PHG","epa_mcl_value":0.01,"status":"exceeds_guideline","detection_limit":null},{"name":"Chromium (total)","code":"CHROMIUM","cas_number":"7440-47-3","group":"inorganics","section":"other_detected","measured_value":0.08,"unit":"ug/L","sample_date":"2007-10-15","source":"WQP","source_scope":"regional_groundwater","health_guideline_value":0.1,"health_guideline_source":"EPA MCLG","epa_mcl_value":0.1,"status":"below_limits","detection_limit":null},{"name":"Lead (90th Percentile)","code":"PB90","cas_number":"7439-92-1","group":"lead_copper","section":"other_detected","measured_value":0,"unit":"mg/L","sample_date":"2024-12-31","source":"EPA ECHO","source_scope":"federal_program","health_guideline_value":0.0002,"health_guideline_source":"OEHHA PHG","epa_mcl_value":null,"status":"below_limits","detection_limit":null},{"name":"Copper (90th Percentile)","code":"COPPER","cas_number":"7440-50-8","group":"lead_copper","section":"other_detected","measured_value":0.24,"unit":"ug/L","sample_date":"2017-05-31","source":"WQP","source_scope":"regional_groundwater","health_guideline_value":0.3,"health_guideline_source":"OEHHA PHG","epa_mcl_value":null,"status":"below_limits","detection_limit":null}],"sources":[{"name":"DNR","url":"https://apps.dnr.wi.gov/dwsportalpub"},{"name":"WQP","url":"https://www.waterqualitydata.us/"},{"name":"EPA ECHO","url":"https://echo.epa.gov/"}],"pfas_combined_display":null,"well_counts":{"active":2,"retired":4,"facilities_synced_at":"2026-11-02T01:09:07.370Z"},"historical_wells":[],"has_only_historical_data":false,"pfas_hazard_index":null,"tthm_lraa":[],"haa5_lraa":[]}